欢迎来到xxx有限公司

热门关键词: 厕具 学生心理咨询  婚恋情感咨询  心理障碍疏导 

当前位置: 首页 > 客户案例 > unipulse Force measurement F805A

江西unipulse Force measurement F805A

产品分类: 客户案例
Graphic display/ touch panel type digital indicator for voltage and current output

    unipulse Force measurement F377A Graphic display/ touch panel type digital indicator for voltage and current output

    Product outline

    F377A is a digital indicator integrated with a voltage / current output type sensor that can display physical quantities such as pressure, load and torque in waveforms. It can be connected to the voltage of ±10 V and the current of ±20 mA. It is able to visually capture in waveforms the fluctuations in physical quantities which are difficult to capture by only numerical values.
    With a maximum 2000 times per second for high-speed processing, it is also ideal for narrow value fluctuations and comes equipped with a HI/LO limit comparison function, various hold functions and judgment function.
    F377A is the best digital indicator for graders and testers used in results judgment of assembling work and auto machining.

    Specifications

    Analog section
    Voltage input -10 to +10 V, Input impedance 1 MΩ or more
    Current input -20 to +20 mA, Input resistance Approx.250 Ω
    Accuracy Non-linearity: within 0.02% FS±1 digit (at a 10 V or 20 mA input)
    Zero drift: within 0.2 mV/℃ RTI or within 0.4 μA/℃ RTI
    Gain drift: within 0.01%/℃
    Analog filter Low pass filter (-6 dB/oct.)
    Selectable at 30, 100, 300, 1000 Hz
    A/D converter Speed: 2000 times/sec.
    Resolution: 24 bit (binary)
    Effective resolution: Approx. 1/30000 to 10 V or 20 mA input
    Analog monitor output Output level: Approx. 0.6 V per 1 V input or approx. 0.3 V per 1 mA input
    Load resistance: 2 kΩ or higher
     
    Display section
    Display unit TFT color LCD module 3.5 inch
    Display area 71(W) mm × 53(H) mm
    Dot structure 320 × 240 dot
    Measured value 5 digits: -99999 to +99999, Sign: Minus sign on most significant digit
     
    Setting section
    Comparison functions HH, Hi, Lo, LL, Hysteresis, alarm Hi, alarm Lo, near zero, comparison timing, comparison output selection
    Hold setting Hold mode, detection start level, detection time, level detection condition, sample point shift value, detection end level, average sample number, inflection point judging value, pre-inflection point slope detection time, post-inflection point slope detection time, inflection point shift, detection start condition, peak-valley detection min. value, peak-valley detection amplification
    Graph setting Graph mode, Y-axis (load) start point, Y-axis (load) end point, X-axis (time) end point, plotting start level, interval time, plotting start level conditions
    Calibration setting Analog input selection, zero calibration, equivalent input calibration, actual load calibration, calibration value selection, unit, minimum scale, digital offset, digital zero limit
    Operation setting Digital filter, analog filter, backlight lighting time, language change, SI/F print, motion detect, zero tracking, monitor output filter, display color of measured value, B5 function selection, B6 OFF detection standby time, B8 OFF detection standby time, measured work input change, control input change, password
    RS-232C setting Communication mode, baud rate, character length, stop bit, parity bit, delimiter, flow control
    Extended comparison function Previous value comparison, relative value comparison
    Extended hold function Double hold, auto reset change, hold value update, sample trigger change, hold cancel at DZ, hold END timing
    Extended graph function Pre-trigger display
    Extended operation function Digital filter characteristics, average time at DZ, RUN output format
    Extended option BCD output data format
     
    Hold section
    Hold 1) Sample, 2) Peak, 3) Valley, 4) P-P, 5) Average, 6) Inflection Point, 7) Relative Maximum, 8) Relative Minimum, 9) Relative Difference, 10) Sample & Peak, 11) Sample & Valley, 12) Sample & P-P, 13) Sample & Average, 14) Sample & Inflection Point, 15) Sample & Relative Maximum, 16) Sample & Relative Minimum, 17) Sample & Relative Difference, 18) Peak & Valley, 19) Peak & P-P, 20) Valley & P-P, 21) Average & Peak, 22) Average & Valley, 23) Average & P-P, 24) Relative Maximum & Relative Minimum, 25) Relative Maximum & Relative Difference, 26) Relative Minimum & Relative Difference
     
    Comparison function
    Higher Hi (HH) limit setting, Lower Lo (LL) limit setting, High (HI) limit setting, Low (LO) limit setting
     
    Calibration value selection
    Stores up to 4 types of calibration value that can be interchanged
     
    External signal
    External output signal (8 points) HI/LO comparison output (HH, HI, OK, LO, LL)/ RUN output/ hold end output/ graph plotting end output
    Vce = 30 V (max), Ic = 30 mA (max)
    External input signal (10 points) Work selection input/ hold control input/ digital zero input (DZ)/ graph plotting control input/ calibration selection input
    lc = 10 mA or lower
     
    Interface
    SIF 2-wire type serial interface
    232 RS-232C communication interface
    BCO BCD parallel data output interface (Option)
    DAV D/A converter voltage output (Option)
    DAI D/A converter current output (Option)
    ODN DeviceNet interface (Option)
    CCL CC-Link interface (Option)
     
    General specifications
    Power supply voltage DC 24 V (±15%)
    Power consumption 18 W max
    Operating conditions Operation temperature -10℃ to +40℃
    Storage temperature -20℃ to +60℃
    Humidity: 85% RH or lower (non-condensing)
    Inrush current (typ) 55 A, 1 msec (cold start at room temperature)
    Dimensions 96(W) × 96(H) × 138(D) mm (Not including projections)
    Weight Approx. 1.0 kg
     
    Attachments
    FCN series I/O connector (with cover) 1
    Jumper wire 1
    Operation manual 1
    BCD output connector (when BCD output option is installed) 1
    Mini driver
    (when D/A converter option is installed)
    1
    DeviceNet connector
    (when DeviceNet option is installed)
    1
    CC-Link connector
    (when CC-Link option is installed)
    1
     

    Option

    Model
    BCO BCD parallel data output interface
    DAV D/A converter voltage output
    DAI D/A converter current output
    CCL CC-Link interface
    ODN DeviceNet interface
     

    Optional accessories

    Model
    CA372-I/O end treatment 24-leads cable with FCN connector at one end 3 m
    CA81-232X miniDIN-D-Sub9p cross cable 1.5 m
    CN50 FCN series I/O connector (with cover)
    CN55 FCN series I/O connector (with diagonal cover)
    CN60 Circular DIN 8p connector for RS-232C
    CN51 BCD output connector
    CN71 CC-Link connector
    CN80 Analog I/O connector terminal
    CND01 DeviceNet connector
    GMP96 × 96 Rubber packing



    Please note that there are possibilities of individual differences in a color tone on display devices such as LEDs, fluorescent display tubes and LCDs due to manufacturing process or production lots.



    Structure of product code

    F377A_product-code

    Download

    Product catalogue(PDF)
    ⇒Download Page
    Operation manual(PDF)
    External dimension
    DXF
    (ZIP)
    PDF
    Support tools
    Software

    相关资讯

    联系我们

    联系电话一:18866860691

    免费热线:18866860691 QQ: